package org.yamcs.xtce; import java.io.Serializable; /** * Alarms associated with numeric data types * @author nm * */ public class NumericAlarm extends AlarmType implements Serializable { private static final long serialVersionUID = 200706052351L; /** * StaticAlarmRanges are used to trigger alarms when the parameter value * passes some threshold value (as opposed to delta alarms or other fancy alarms not supported by yamcs). */ private AlarmRanges staticAlarmRanges=new AlarmRanges(); /** * ChangeAlarmRanges are used to trigger alarms when the parameter value's rate-of-change is either too fast or too slow. * The change may be with respect to time (the default) or with respect to samples (delta alarms) * - the changeType attribute determines this. * The change may also be either relative (as a percentage change) or absolute as set by the changeBasis attribute. * The alarm also requires the spanOfInterest in both samples and seconds to have passed before it is to trigger. * For time based rate of change alarms, the time specified in spanOfInterestInSeconds is used to calculate the change. * For sample based rate of change alarms, the change is calculated over the number of samples specified in spanOfInterestInSeconds. */ private AlarmRanges changeAlarmRanges = null; public AlarmRanges getStaticAlarmRanges() { return staticAlarmRanges; } public void setStaticAlarmRanges(AlarmRanges staticAlarmRanges) { this.staticAlarmRanges = staticAlarmRanges; } @Override public String toString() { return getStaticAlarmRanges().toString(); } }