//License
/***
* Java Modbus Library (jamod)
* Copyright (c) 2002-2004, jamod development team
* All rights reserved.
*
* Redistribution and use in source and binary forms, with or without
* modification, are permitted provided that the following conditions are
* met:
*
* Redistributions of source code must retain the above copyright notice,
* this list of conditions and the following disclaimer.
*
* Redistributions in binary form must reproduce the above copyright notice,
* this list of conditions and the following disclaimer in the documentation
* and/or other materials provided with the distribution.
*
* Neither the name of the author nor the names of its contributors
* may be used to endorse or promote products derived from this software
* without specific prior written permission.
*
* THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDER AND CONTRIBUTORS ``AS
* IS'' AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO,
* THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR
* PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE REGENTS OR CONTRIBUTORS BE
* LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR
* CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF
* SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS
* INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN
* CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE)
* ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE
* POSSIBILITY OF SUCH DAMAGE.
***/
package net.wimpi.modbus.msg;
import java.io.ByteArrayInputStream;
import java.io.DataInputStream;
import java.io.IOException;
import net.wimpi.modbus.Modbus;
/**
* Abstract class implementing a <tt>ModbusResponse</tt>.
* This class provides specialised implementations with
* the functionality they have in common.
*
* @author Dieter Wimberger
* @version 1.2rc2 (14/04/2014)
*/
public abstract class ModbusResponse
extends ModbusMessageImpl {
/**
* Utility method to set the raw data of the message.
* Should not be used except under rare circumstances.
* <p>
* @param msg the <tt>byte[]</tt> resembling the raw modbus
* response message.
*/
protected void setMessage(byte[] msg) {
try {
readData(
new DataInputStream(
new ByteArrayInputStream(msg)
)
);
} catch (IOException ex) {
}
}//setMessage
/**
* Factory method creating the required specialized <tt>ModbusResponse</tt>
* instance.
*
* @param functionCode the function code of the response as <tt>int</tt>.
* @return a ModbusResponse instance specific for the given function code.
*/
public static ModbusResponse createModbusResponse(int functionCode) {
ModbusResponse response = null;
switch (functionCode) {
case Modbus.READ_MULTIPLE_REGISTERS:
response = new ReadMultipleRegistersResponse();
break;
case Modbus.READ_INPUT_DISCRETES:
response = new ReadInputDiscretesResponse();
break;
case Modbus.READ_INPUT_REGISTERS:
response = new ReadInputRegistersResponse();
break;
case Modbus.READ_COILS:
response = new ReadCoilsResponse();
break;
case Modbus.WRITE_MULTIPLE_REGISTERS:
response = new WriteMultipleRegistersResponse();
break;
case Modbus.WRITE_SINGLE_REGISTER:
response = new WriteSingleRegisterResponse();
break;
case Modbus.WRITE_COIL:
response = new WriteCoilResponse();
break;
case Modbus.WRITE_MULTIPLE_COILS:
response = new WriteMultipleCoilsResponse();
break;
default:
response = new ExceptionResponse();
break;
}
return response;
}//createModbusResponse
}//class ModbusResponse