//License /*** * Java Modbus Library (jamod) * Copyright (c) 2002-2004, jamod development team * All rights reserved. * * Redistribution and use in source and binary forms, with or without * modification, are permitted provided that the following conditions are * met: * * Redistributions of source code must retain the above copyright notice, * this list of conditions and the following disclaimer. * * Redistributions in binary form must reproduce the above copyright notice, * this list of conditions and the following disclaimer in the documentation * and/or other materials provided with the distribution. * * Neither the name of the author nor the names of its contributors * may be used to endorse or promote products derived from this software * without specific prior written permission. * * THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDER AND CONTRIBUTORS ``AS * IS'' AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, * THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR * PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE REGENTS OR CONTRIBUTORS BE * LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR * CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF * SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS * INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN * CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) * ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE * POSSIBILITY OF SUCH DAMAGE. ***/ package net.wimpi.modbus.io; import net.wimpi.modbus.Modbus; import net.wimpi.modbus.ModbusCoupler; import net.wimpi.modbus.ModbusIOException; import net.wimpi.modbus.msg.ModbusMessage; import net.wimpi.modbus.msg.ModbusRequest; import net.wimpi.modbus.msg.ModbusResponse; import net.wimpi.modbus.util.ModbusUtil; import java.io.DataInputStream; import java.io.IOException; import java.io.InputStream; import java.io.OutputStream; /** * Class that implements the Modbus/ASCII transport * flavor. * * @author Dieter Wimberger * @author John Charlton * @version 1.2rc2 (14/04/2014) */ public class ModbusASCIITransport extends ModbusSerialTransport { private DataInputStream m_InputStream; //used to read from private ASCIIOutputStream m_OutputStream; //used to write to private byte[] m_InBuffer; private BytesInputStream m_ByteIn; //to read message from private BytesOutputStream m_ByteInOut; //to buffer message to private BytesOutputStream m_ByteOut; //write frames /** * Constructs a new <tt>MobusASCIITransport</tt> instance. */ public ModbusASCIITransport() { }//constructor public void close() throws IOException { m_InputStream.close(); m_OutputStream.close(); }//close public void writeMessage(ModbusMessage msg) throws ModbusIOException { try { synchronized (m_ByteOut) { //write message to byte out msg.setHeadless(); msg.writeTo(m_ByteOut); byte[] buf = m_ByteOut.getBuffer(); int len = m_ByteOut.size(); //write message m_OutputStream.write(FRAME_START); //FRAMESTART m_OutputStream.write(buf, 0, len); //PDU if(Modbus.debug) System.out.println("Writing: " + ModbusUtil.toHex(buf, 0, len)); m_OutputStream.write(ModbusUtil.calculateLRC(buf, 0, len)); //LRC m_OutputStream.write(FRAME_END); //FRAMEEND m_OutputStream.flush(); m_ByteOut.reset(); // clears out the echoed message // for RS485 if (m_Echo) { // read back the echoed message readEcho(len + 3); } } } catch (Exception ex) { throw new ModbusIOException("I/O failed to write" + ex); } }//writeMessage public ModbusRequest readRequest() throws ModbusIOException { boolean done = false; ModbusRequest request = null; int in = -1; try { do { //1. Skip to FRAME_START while ((in = m_InputStream.read()) != FRAME_START) ; //2. Read to FRAME_END synchronized (m_InBuffer) { m_ByteInOut.reset(); while ((in = m_InputStream.read()) != FRAME_END) { if (in == -1) { throw new IOException("readRequest: I/O exception - Serial port timeout."); } m_ByteInOut.writeByte(in); } //check LRC if (((int)m_InBuffer[m_ByteInOut.size()-1] & 0xff) != ModbusUtil.calculateLRC(m_InBuffer, 0, m_ByteInOut.size()-1)) { continue; } ; m_ByteIn.reset(m_InBuffer, m_ByteInOut.size()); in = m_ByteIn.readUnsignedByte(); //check message with this slave unit identifier if (in != ModbusCoupler.getReference().getUnitID()) { continue; } in = m_ByteIn.readUnsignedByte(); //create request request = ModbusRequest.createModbusRequest(in); request.setHeadless(); //read message m_ByteIn.reset(m_InBuffer, m_ByteInOut.size()); request.readFrom(m_ByteIn); } done = true; } while (!done); return request; } catch (Exception ex) { if(Modbus.debug) System.out.println(ex.getMessage()); throw new ModbusIOException("readRequest: I/O exception - failed to read."); } }//readRequest public ModbusResponse readResponse() throws ModbusIOException { boolean done = false; ModbusResponse response = null; int in = -1; try { do { //1. Skip to FRAME_START while ((in = m_InputStream.read()) != FRAME_START) { if (in == -1) { throw new IOException("readResponse: I/O exception - Serial port timeout."); } } //2. Read to FRAME_END synchronized (m_InBuffer) { m_ByteInOut.reset(); while ((in = m_InputStream.read()) != FRAME_END) { if (in == -1) { throw new IOException("I/O exception - Serial port timeout."); } m_ByteInOut.writeByte(in); } int len = m_ByteInOut.size(); if (Modbus.debug) System.out.println("Received: " + ModbusUtil.toHex(m_InBuffer, 0, len)); //check LRC if (((int)m_InBuffer[len-1] & 0xff) != ModbusUtil.calculateLRC(m_InBuffer, 0, len - 1)) { if (Modbus.debug) System.out.println("LRC is wrong: received=" + ((int)m_InBuffer[len-1] & 0xff) + " calculated=" + ModbusUtil.calculateLRC(m_InBuffer, 0, len - 1)); continue; } m_ByteIn.reset(m_InBuffer, m_ByteInOut.size()); in = m_ByteIn.readUnsignedByte(); // JDC: To check slave unit identifier in a response we need to know // the slave id in the request. This is not tracked since slaves // only respond when a master request is made and there is only one // master. We are the only master, so we can assume that this // response message is from the slave responding to the last request. // if (in != ModbusCoupler.getReference().getUnitID()) { // continue; // } in = m_ByteIn.readUnsignedByte(); //create request response = ModbusResponse.createModbusResponse(in); response.setHeadless(); //read message m_ByteIn.reset(m_InBuffer, m_ByteInOut.size()); response.readFrom(m_ByteIn); } done = true; } while (!done); return response; } catch (Exception ex) { if(Modbus.debug) System.out.println(ex.getMessage()); throw new ModbusIOException("readResponse I/O exception - failed to read."); } }//readResponse /** * Prepares the input and output streams of this * <tt>ModbusASCIITransport</tt> instance. * The raw input stream will be wrapped into a * filtered <tt>DataInputStream</tt>. * * @param in the input stream to be used for reading. * @param out the output stream to be used for writing. * @throws IOException if an I\O related error occurs. */ public void prepareStreams(InputStream in, OutputStream out) throws IOException { m_InputStream = new DataInputStream(new ASCIIInputStream(in)); m_OutputStream = new ASCIIOutputStream(out); m_ByteOut = new BytesOutputStream(Modbus.MAX_MESSAGE_LENGTH); m_InBuffer = new byte[Modbus.MAX_MESSAGE_LENGTH]; m_ByteIn = new BytesInputStream(m_InBuffer); m_ByteInOut = new BytesOutputStream(m_InBuffer); }//prepareStreams /** * Defines a virtual number for the FRAME START token (COLON). */ public static final int FRAME_START = 1000; /** * Defines a virtual number for the FRAME_END token (CR LF). */ public static final int FRAME_END = 2000; }//class ModbusASCIITransport