//License
/***
* Java Modbus Library (jamod)
* Copyright (c) 2002-2004, jamod development team
* All rights reserved.
*
* Redistribution and use in source and binary forms, with or without
* modification, are permitted provided that the following conditions are
* met:
*
* Redistributions of source code must retain the above copyright notice,
* this list of conditions and the following disclaimer.
*
* Redistributions in binary form must reproduce the above copyright notice,
* this list of conditions and the following disclaimer in the documentation
* and/or other materials provided with the distribution.
*
* Neither the name of the author nor the names of its contributors
* may be used to endorse or promote products derived from this software
* without specific prior written permission.
*
* THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDER AND CONTRIBUTORS ``AS
* IS'' AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO,
* THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR
* PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE REGENTS OR CONTRIBUTORS BE
* LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR
* CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF
* SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS
* INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN
* CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE)
* ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE
* POSSIBILITY OF SUCH DAMAGE.
***/
package net.wimpi.modbus.msg;
import java.io.DataInput;
import java.io.DataOutput;
import java.io.IOException;
import net.wimpi.modbus.Modbus;
import net.wimpi.modbus.util.ModbusUtil;
/**
* Abstract class implementing a <tt>ModbusMessage</tt>.
* This class provides specialised implementations with
* the functionality they have in common.
*
* @author Dieter Wimberger
* @version 1.2rc2 (14/04/2014)
*/
public abstract class ModbusMessageImpl
implements ModbusMessage {
//instance attributes
private int m_TransactionID = Modbus.DEFAULT_TRANSACTION_ID;
private int m_ProtocolID = Modbus.DEFAULT_PROTOCOL_ID;
private int m_DataLength;
private int m_UnitID = Modbus.DEFAULT_UNIT_ID;
private int m_FunctionCode;
private boolean m_Headless = false; //flag for headerless (serial) transport
/*** Header ******************************************/
/**
* Tests if this message instance is headless.
*
* @return true if headless, false otherwise.
*/
public boolean isHeadless() {
return m_Headless;
}//isHeadless
public void setHeadless() {
m_Headless = true;
}//setHeadless
/**
* Sets the headless flag of this message.
*
* @param b true if headless, false otherwise.
*/
protected void setHeadless(boolean b) {
m_Headless = b;
}//setHeadless
public int getTransactionID() {
return m_TransactionID;
}//getTransactionID
/**
* Sets the transaction identifier of this
* <tt>ModbusMessage</tt>.<p>
* The identifier should be a 2-byte (short) non negative
* integer value valid in the range of 0-65535.<br>
* <p>
* @param tid the transaction identifier as <tt>int</tt>.
*/
public void setTransactionID(int tid) {
m_TransactionID = tid;
//setChanged(true);
}//setTransactionID
public int getProtocolID() {
return m_ProtocolID;
}//getProtocolID
/**
* Sets the protocol identifier of this
* <tt>ModbusMessage</tt>.<p>
* The identifier should be a 2-byte (short) non negative
* integer value valid in the range of 0-65535.<br>
* <p>
* @param pid the protocol identifier as <tt>int</tt>.
*/
public void setProtocolID(int pid) {
m_ProtocolID = pid;
//setChanged(true);
}//setProtocolID
public int getDataLength() {
return m_DataLength;
}//getDataLength
/**
* Sets the length of the data appended
* after the protocol header.<p>
* Note that this library, a bit in contrast to the
* specification, counts the unit identifier and the
* function code to the header, because it is part
* of each and every message. Thus this message will
* append two (2) to the passed in integer value.
* <p>
* @param length the data length as <tt>int</tt>.
*/
public void setDataLength(int length) {
//should be below 255, check!
m_DataLength = length + 2;
}//setData
public int getUnitID() {
return m_UnitID;
}//getUnitID
/**
* Sets the unit identifier of this
* <tt>ModbusMessage</tt>.<br>
* The identifier should be a 1-byte non negative
* integer value valid in the range of 0-255.
*
* @param num the unit identifier number to be set.
*/
public void setUnitID(int num) {
m_UnitID = num;
//setChanged(true);
}//setUnitID
public int getFunctionCode() {
return m_FunctionCode;
}//getFunctionCode
/**
* Sets the function code of this <tt>ModbusMessage</tt>.<br>
* The function code should be a 1-byte non negative
* integer value valid in the range of 0-127.<br>
* Function codes are ordered in conformance
* classes their values are specified in
* <tt>net.wimpi.modbus.Modbus</tt>.
*
* @param code the code of the function to be set.
* @see net.wimpi.modbus.Modbus
*/
protected void setFunctionCode(int code) {
m_FunctionCode = code;
//setChanged(true);
}//setFunctionCode
/*** Data ********************************************/
/*** Transportable ***********************************/
/**
* Writes this message to the given <tt>DataOutput</tt>.
*
* @param dout a <tt>DataOutput</tt> instance.
* @throws IOException if an I/O related error occurs.
*/
public void writeTo(DataOutput dout)
throws IOException {
if (!isHeadless()) {
dout.writeShort(getTransactionID());
dout.writeShort(getProtocolID());
dout.writeShort(getDataLength());
}
dout.writeByte(getUnitID());
dout.writeByte(getFunctionCode());
writeData(dout);
}//writeTo
/**
* Writes the subclass specific data to the given DataOutput.
*
* @param dout the DataOutput to be written to.
* @throws IOException if an I/O related error occurs.
*/
public abstract void writeData(DataOutput dout)
throws IOException;
public void readFrom(DataInput din)
throws IOException {
if (!isHeadless()) {
setTransactionID(din.readUnsignedShort());
setProtocolID(din.readUnsignedShort());
m_DataLength = din.readUnsignedShort();
}
setUnitID(din.readUnsignedByte());
setFunctionCode(din.readUnsignedByte());
readData(din);
}//readFrom
/**
* Reads the subclass specific data from the given DataInput instance.
*
* @param din the DataInput to read from.
* @throws IOException if an I/O related error occurs.
*/
public abstract void readData(DataInput din)
throws IOException;
public int getOutputLength() {
int l = 2 + getDataLength();
if (!isHeadless()) {
l = l + 6;
}
return l;
}//getOutputLength
/*** END Transportable *******************************/
/**
* Returns the this message as hexadecimal string.
*
* @return the message as hex encoded string.
*/
public String getHexMessage() {
return ModbusUtil.toHex(this);
}//getHexMessage