/*
* eGov suite of products aim to improve the internal efficiency,transparency,
* accountability and the service delivery of the government organizations.
*
* Copyright (C) <2015> eGovernments Foundation
*
* The updated version of eGov suite of products as by eGovernments Foundation
* is available at http://www.egovernments.org
*
* This program is free software: you can redistribute it and/or modify
* it under the terms of the GNU General Public License as published by
* the Free Software Foundation, either version 3 of the License, or
* any later version.
*
* This program is distributed in the hope that it will be useful,
* but WITHOUT ANY WARRANTY; without even the implied warranty of
* MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
* GNU General Public License for more details.
*
* You should have received a copy of the GNU General Public License
* along with this program. If not, see http://www.gnu.org/licenses/ or
* http://www.gnu.org/licenses/gpl.html .
*
* In addition to the terms of the GPL license to be adhered to in using this
* program, the following additional terms are to be complied with:
*
* 1) All versions of this program, verbatim or modified must carry this
* Legal Notice.
*
* 2) Any misrepresentation of the origin of the material is prohibited. It
* is required that all modified versions of this material be marked in
* reasonable ways as different from the original version.
*
* 3) This license does not grant any rights to any user of the program
* with regards to rights under trademark law for use of the trade names
* or trademarks of eGovernments Foundation.
*
* In case of any queries, you can reach eGovernments Foundation at contact@egovernments.org.
*/
package org.egov.wtms.application.entity;
import org.egov.infra.persistence.entity.AbstractAuditable;
import org.egov.wtms.masters.entity.RoadCategory;
import org.hibernate.validator.constraints.Length;
import org.hibernate.validator.constraints.SafeHtml;
import javax.persistence.Entity;
import javax.persistence.FetchType;
import javax.persistence.GeneratedValue;
import javax.persistence.GenerationType;
import javax.persistence.Id;
import javax.persistence.JoinColumn;
import javax.persistence.ManyToOne;
import javax.persistence.SequenceGenerator;
import javax.persistence.Table;
import javax.validation.constraints.NotNull;
@Entity
@Table(name = "egwtr_fieldinspection_details")
@SequenceGenerator(name = FieldInspectionDetails.SEQ_FIELDINSPECTIONDETAILS, sequenceName = FieldInspectionDetails.SEQ_FIELDINSPECTIONDETAILS, allocationSize = 1)
public class FieldInspectionDetails extends AbstractAuditable {
private static final long serialVersionUID = 4381725568940895413L;
public static final String SEQ_FIELDINSPECTIONDETAILS = "SEQ_EGWTR_FIELDINSPECTION_DETAILS";
@Id
@GeneratedValue(generator = SEQ_FIELDINSPECTIONDETAILS, strategy = GenerationType.SEQUENCE)
private Long id;
@NotNull
@ManyToOne(fetch = FetchType.LAZY)
@JoinColumn(name = "connectiondetailsid", nullable = false)
private WaterConnectionDetails waterConnectionDetails;
@ManyToOne
@JoinColumn(name = "roadcategory")
private RoadCategory roadCategory;
@SafeHtml
@Length(max = 50)
private String existingPipeline;
private double pipelineDistance;
@NotNull
private double estimationCharges;
@Override
public Long getId() {
return id;
}
@Override
public void setId(final Long id) {
this.id = id;
}
public WaterConnectionDetails getWaterConnectionDetails() {
return waterConnectionDetails;
}
public void setWaterConnectionDetails(final WaterConnectionDetails waterConnectionDetails) {
this.waterConnectionDetails = waterConnectionDetails;
}
public RoadCategory getRoadCategory() {
return roadCategory;
}
public void setRoadCategory(final RoadCategory roadCategory) {
this.roadCategory = roadCategory;
}
public String getExistingPipeline() {
return existingPipeline;
}
public void setExistingPipeline(final String existingPipeline) {
this.existingPipeline = existingPipeline;
}
public double getPipelineDistance() {
return pipelineDistance;
}
public void setPipelineDistance(final double pipelineDistance) {
this.pipelineDistance = pipelineDistance;
}
public double getEstimationCharges() {
return estimationCharges;
}
public void setEstimationCharges(final double estimationCharges) {
this.estimationCharges = estimationCharges;
}
}