* SDMData.java - 25/01/2016 5:42:42 pm
*
* Copyright 2007-2016 SolarNetwork.net Dev Team
*
* This program is free software; you can redistribute it and/or
* modify it under the terms of the GNU General Public License as
* published by the Free Software Foundation; either version 2 of
* the License, or (at your option) any later version.
*
* This program is distributed in the hope that it will be useful,
* but WITHOUT ANY WARRANTY; without even the implied warranty of
* MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the GNU
* General Public License for more details.
*
* You should have received a copy of the GNU General Public License
* along with this program; if not, write to the Free Software
* Foundation, Inc., 59 Temple Place, Suite 330, Boston, MA
* 02111-1307 USA
* ==================================================================
*/
package net.solarnetwork.node.hw.deson.meter;
import java.util.Map;
import net.solarnetwork.node.domain.ACPhase;
import net.solarnetwork.node.domain.GeneralNodeACEnergyDatum;
import net.solarnetwork.node.io.modbus.ModbusConnection;
/**
* Common API for SDM meter data.
*
* @author matt
* @version 1.2
*/
public interface SDMData {
/**
* Test if a particular phase is supported by the device. The SDM-120, for
* example, only supports a single phase. Also the SDM-360 might be
* configured in a single phase (two wire) configuration.
*
* @param phase
* The phase to test.
* @return <em>true</em> if the given {@code phase} is supported
* @since 1.1
*/
boolean supportsPhase(ACPhase phase);
/**
* Get the system time meter data was read from the actual device. If never
* read, then return {@code 0}.
*
* @return the data timestamp
*/
long getMeterDataTimestamp();
/**
* Get the system time control data was read from the actual device. If
* never read, then return {@code 0}.
*
* @return the control data timestamp
*/
long getControlDataTimestamp();
/**
* Read data from the meter and store it internally. If data is populated
* successfully, {@link #getMeterDataTimestamp()} will be updated to reflect
* the current system time.
*
* @param conn
* the Modbus connection
*/
void readMeterData(final ModbusConnection conn);
/**
* Read control (holding) data from the meter and store it internally. If
* data is populated successfully, {@link #getControlDataTimestamp()} will
* be updated to reflect the current system time.
*
* @param conn
* the Modbuss connection
*/
void readControlData(final ModbusConnection conn);
/**
* Get a copy of the data.
*
* @return Get a new instance with a copy of the data.
*/
SDMData getSnapshot();
/**
* Get a string representation of the meter data, for debugging purposes.
*
* The generated string will contain prefix and suffix lines, with any
* number of lines between that contain a register address followed by two
* register values per line, printed as hexidecimal integers. For example:
*
* <pre>
* SDMData{
* 30001: 0x4141, 0x727E
* 30007: 0xFFC0, 0x0000
* ...
* 30345: 0x0000, 0x0000
* }
* </pre>
*
* @return A debug string.
*/
String dataDebugString();
/**
* Get information about the meter, such as the model number, manufacture
* date, etc.
*
* @return Meter information, or <em>null</em> if none available.
*/
Map<String, Object> getDeviceInfo();
/**
* Get a brief information message about the operational status of the
* meter, such as the overall power being used, etc.
*
* @return A brief status message, or <em>null</em> if none available.
*/
String getOperationStatusMessage();
/**
* Populate an {@code ACEnergyDatum} from sample data for a specific phase.
*
* @param phase
* The phase to populate data for.
* @param datum
* The datum to populate data into.
*/
void populateMeasurements(ACPhase phase, GeneralNodeACEnergyDatum datum);
/**
* Get an effective voltage value in V. Only valid after
* {@link #readMeterData(ModbusConnection)} called at least once.
*
* @param addr
* the register address to read
* @return the value interpreted as a voltage value
*/
Float getVoltage(int addr);
/**
* Get an effective current value in A. Only valid after
* {@link #readMeterData(ModbusConnection)} called at least once.
*
* @param addr
* the register address to read
* @return the value interpreted as a current value
*/
Float getCurrent(int addr);
/**
* Get an effective frequency value in Hz. Only valid after
* {@link #readMeterData(ModbusConnection)} called at least once.
*
* @param addr
* the register address to read
* @return the value interpreted as a frequency value
*/
Float getFrequency(int addr);
/**
* Get an effective power factor value. Only valid after
* {@link #readMeterData(ModbusConnection)} called at least once.
*
* @param addr
* the register address to read
* @return the value interpreted as a power factor value
*/
Float getPowerFactor(int addr);
/**
* Get an effective power value in W (active), Var (reactive) or VA
* (apparent). These are rounded from their native floating point
* representations. Only valid after
* {@link #readMeterData(ModbusConnection)} called at least once.
*
* @param addr
* the register address to read
* @return the value interpreted as a power value
*/
Integer getPower(int addr);
/**
* Get an effective energy value in Wh (real), Varh (reactive). Only valid
* after {@link #readMeterData(ModbusConnection)} called at least once.
*
* @param addr
* the register address to read
* @return the value interpreted as an energy value
*/
Long getEnergy(int addr);
/**
* Get the <em>backwards</em> flag. When {@code true} then treat the meter
* as being installed backwards with respect to the current direction. In
* this case certain instantaneous measurements will be negated and certain
* accumulating properties will be switched (like {@code wattHours} and
* {@code wattHoursReverse}) when {@link #populateMeasurements} is called.
*
* @return the backwards flag
* @since 1.2
*/
boolean isBackwards();
}